NOTES:
1. Allowable uniform loads are based upon equal span lengths.
2. Positive Wind is wind pressure and is not increased by 33 1/3%.
3. Negative Wind is wind suction or uplift and is not increased by
33 1/3%.
4. Live is the allowable live or snow load.
5. Deflection (L/180) is the allowable load that limits the panels
deflection to L/180.
6. Deflection (L/240) is the allowable load that limits the panels
deflection to L/240.
7. The weight of the panel has not been deducted from the
allowable loads.
8. Positive Wind, Negative Wind, and Live Load values are limited
to combined shear & bending using Eq. C3.3.1-1 of the AISI
Specification.
9. Positive Wind and Live Load values are limited by web
crippling using a bearing length of 2".
10.Web crippling values are determined using a ratio of the uniform
load actually supported by the top flanges of the section. |